Application Conditions
and Storage
Both the Tilesafe
Reinforcing Tape and the Tilesafe
Membrane are presented in roll form. The upper side
has a visible grid and is protected with a plastic release
film, the lower side has a smooth adhesive and is protected
by a paper release. The upper release film is normally
left in place until the sheet is covered with another
material.
Care should be taken to ensure the temperature is at
least 10 °C. Conditioning of the membrane in a warm
area prior to use will enhance its adhesion properties
during application. Tilesafe
and ancillary products should be stored in original
cartons, upright and out of direct sunlight, below 35
°C and should be protected from frost. Cartons should
not be overstacked. Prior to commencing applications
for the day, ensure availability of all required materials
and tools.
Surface Preparation
All safety data sheets and local
health and safety regulations must be observed at all
times.
The surface must be clean, dry, free from dust, grease
and oil. All indentations should be filled and any protrusions
struck off.
Contaminated or dusty surfaces should be cleaned, an
anti-fungicide wash can be used to remove and destroy
any biological growth. In cases where the substrate
is masonry, suitable high pressure water jetting may
also be used. Ensure the substrate is fully dry prior
to the application of primer.
Oily or greasy surfaces
should be cleaned with a suitable proprietary cleaner
and thoroughly rinsed then allowed to dry.
Ensure that both the primer and membrane are compatible
with any existing coatings. If in doubt, contact us
at CCL.